站内搜索
|
详细信息 Product Name: 3 Phase Fan Motor Flame Proof Motor Model NO.: YBF2-280M-4 Brand: Pinnxun Certification: ISO9001 CE CCC Starting Mode: Direct on-line Starting Number of Poles: 4 Casing Protection: Explosion-Proof Type Function: Driving Number of Stator: Three-Phase Speed: Constant Speed Application: Industrial Wire: 100% Copper Wire Protection: IP55 AC Voltage: 380,415,440 Ect Output Power: 90kw Warranty Period: in 12 Months Eff: Ie3 Ie2 Ie1 Insulation Class: F Frequency: 50Hz (Also Can Be 60Hz) Temperature Rise: B Usage: Coal Mine or Danger Zone Trademark: Pinnxun Transport Package: Standard Export Wooden Case Specification: IEC standard Origin: Shanghai China HS Code: 850152000 Product Description SpecificationsATEX explosion proof moor for mineIEC:63-355 ATEX certificateExd1 and Exd11BT4ATEX YB2 YB3 YBK2 YBK3 YBF2explosion proof moor for mineFeature and usageYB2 ranges of three-phase induction motors are flame-proof motors obtained by renewal and generation-changing of YB ranges of motors. The performances of the products have come up to advanced international standards.The motors have the advantages of higher efficiency, energy saving, higher locked-rotor torque, lower noise, smaller vibration, safe and reliable operation and beautiful appearance, etc. The outputs, mounting dimensions and their corresponding relationships comply with IEC standards.YB2 series electric motors are designed and manufactured into explosion proof type and the explosion proof property conforms to China National Standards: GB3836.1-2000 Electrical Apparatus for Explosive Gas Atmospheres-General Requirements. GB3836.2-2000 Electrical Apparatus for Explosive Gas Atmospheres- Explosion proof Enclosure d and standards IEC79-1, BS4683 and EN50018. ExdI- safe for use in the non-mining surfaces of underground coal mines where the explosive mixtures of methane or coal-dust are present. ExdIIAT4 - safe for use in plants where the explosive mixtures of IIA Class, TI, T2, T3 or T4 are present. ExdIIBT4 - safe for use in plants where the explosive mixtures of IIB Class, TI, T2, T3 or T4 are present. ExdIICT4 - safe for use in plants where the explosive mixtures of IIC Class, TI, T2, T3 or T4 are present.Exhibition and production of usMotor PerformanceExplosion proof mark:EXD1 EXDIIAT4 EXDIIBT4 EXDIICT4Certificate:IECEX ATEX(for Europe market)Ambient Temperature: -15°C~40°CAltitude: not exceed 1000 MeterRated Voltage: 380V or any voltage between 220-760VRated Frequency: 50Hz/60HzProtection Class: IP55Insulation Class: F/HTemprature rise: B/FCooling Method: IC0141Working Duty: S1(Continuous)Humidity: Lower than 90%Connection: Star-connection for up to 3kW; Delta-connection for 4kW and aboveCertificationToGuaranteeWeareGoodInQualityOordering Informations1.Please indicate the motor type,rated output,rated voltage,rated frequency,synchronous speed,Explosion proof Mark,mounting type,rotation direction(view from the shaft extension side)Use of the environment(indoor or outside)If the user havn't point out the rotation and environment,normailly we think is CW roration and used indoor.2.when user have special requirments,For example:Dispose the stator,bearing explosion proof and bearing temperature sensors,space heater,Plateau use,specical frequency,mounting size change,special output,the user must ,order can be confirm after signing the technical agreement with engneering department . 3.This range of motor can also be made into Variable-Frequency motors,the range of frequency of which is 0-100HZ,the output and overall dimensions should be confirm separately.There are E x d I and ExdIIBT4 type in YB2 ranges of three-phase asynchronous explosion proof motor according to the requirement of the application. The performance of the safety of the products is confirming to the standard of GB3836.1-2000<<Electric Equipment for Using in the Explosive Gas Environment General Equipment, part1:Currency Need>> and GB3836.2-2000<<Electric Equipment for Using in the Explosive Gas Environment General Equipment, part2:Explosion-safe d>>,This ranges of products are suitable for the non-mining working area in underground mine or where there are the explosive gas mixture in factoriesStrongPackageEnsureMotorsafeenoughforShiporTruckTransportationStructure DescriptionYB2 series ac induction motor mounting details:Schematic diagrammounting typeB3B35B5V1mounting Discribtionframe with feet,end-shield without flangeframe with feet,end-shield with flangeframe without feet,end-shield with flangeframe without feet,end-shield with flangeSuitable frameH63-355H63-355H63-280H180-355YB2 series motors are totally enclosed fan cold(TEFC). 5.bearing type-table 2 table 2Horizontalverticalmotor frameDE sideN-DE sideDE sideN-DE side636201-2RZ/Z26201-2RZ/Z26201-2RZ/Z26201-2RZ/Z2716202-2RZ/Z26202-2RZ/Z26202-2RZ/Z26202-2RZ/Z2806204-2RZ/Z26204-2RZ/Z26204-2RZ/Z26204-2RZ/Z2906205-2RZ/Z26205-2RZ/Z26205-2RZ/Z26205-2RZ/Z21006206-2RZ/Z26206-2RZ/Z26206-2RZ/Z26206-2RZ/Z21126206-2RZ/Z26206-2RZ/Z26206-2RZ/Z26206-2RZ/Z21326208-2RZ/Z26208-2RZ/Z26208-2RZ/Z26208-2RZ/Z21606209-2RZ/Z26209-2RZ/Z26209-2RZ/Z26209-2RZ/Z21806211/Z26211/Z26211/Z26211/Z22006312/Z26312/Z26312/Z26312/Z2225(2P)6312/Z26312/Z26312/Z26312/Z2225(4-8P)6313/Z26212/Z26313/Z26312/Z2250(2P)6313/Z2/Z26313/Z16313/Z26313/Z1250(4-8P)6314/Z16213/Z16314/Z16313/Z1280(2P)6314/Z16313/Z16314/Z16313/Z1280(4P)6317/Z16313/Z16317/Z16313/Z1315(2P)6317/Z16317/Z16317/Z16317/Z1315(4-8P)NU3196319/Z1NU3196319/Z1355(2P)6319/Z16319/Z16319/Z16319/Z1355(4-8P)NU3226322/Z1NU322/Z16322/Z1
|